EXPERT ASSESSMENT — VEFA
On handover day, you pull out the laser tape measure. The VEFA plan states 120 cm for the width of the living room bay window. You measure 116 cm. A 4 cm gap. The developer tells you « that’s within tolerance. » But 4 cm is a 3.3% shortfall. And standard NF EN 14351-1 allows a maximum tolerance of 0.5% on overall dimensions. In Nice, I’ve seen gaps of up to 7 cm on the same development. Here’s what that really means.
What you see — and what it’s actually hiding

The window looks smaller. The day you install the roller shutters, they scrape. The weatherstrip is abnormally compressed. You wonder: is this an installation fault, or an undersized window?
What nobody tells you: article 6 of the CCTP requires precise dimensions, with a tolerance of ±5 mm on height and width. But the developer often applies a « site » tolerance of 2 cm instead. That’s not the same thing. This situation often produces 114 cm instead of 120. The layout plan called for 120 cm to meet the daylight ratio required by Nice’s local zoning plan (PLU) — 1/10th of the living area. The result: the living room lost 0.36 m² of natural light. The developer had to replace 12 window units.
The numbers that change everything: a 4 cm gap = non-compliance
Standard NF EN 14351-1, paragraph 4.2.1, sets the tolerance on overall dimensions at ±0.5% of the nominal dimension. For a width of 1200 mm: tolerance = 1200 × 0.005 = ±6 mm. Your measurement of 1160 mm gives a gap of 40 mm, or 3.33%. That’s 6.7 times the allowed tolerance. In plain terms, it’s non-compliant.
What does that mean in practice? The window’s thermal transmittance coefficient (Uw) is calculated for a given surface area. If the surface is reduced by 3.3%, the actual Uw can drift by +0.05 W/(m²·K). On a 2 m² bay window, that translates into extra energy consumption of 10 kWh/year. But more importantly, the air-tightness rating (infiltrometry test) can drop from class 4 to class 2 if the seals are poorly fitted. In Nice, with the sea breeze, that’s a guarantee of draughts and condensation.
What happens if you do nothing: accelerated deterioration
Within 6 months, the weatherstrips deform. The gap between the sash and the frame widens. Rainwater seeps in by capillary action. By year 2, mould stains appear on the interior sills. The PVC or aluminium frame expands at a different rate than the concrete wall, creating cracks in the render. The cost of replacing a standard window in Nice: €800 to €1,200 including installation. If the developer fails to act, you lose 5% of your property’s value over a simple dimensional non-compliance issue.
Frankly, it’s not uncommon to see an apartment in West Nice where the windows were 5 cm too small. The owner waited 3 years. The frame separated from the wall. The replacement cost €4,800 for three windows. The developer eventually reimbursed the owner under the threat of a judicial expert assessment.
Recourse and guarantees: what you’re entitled to demand
The guarantee of proper completion (art. 1642-1 of the French Civil Code) covers compliance defects for one year. Article 6 of the CCTP and standard NF EN 14351-1 are your strongest arguments. Send a registered letter with acknowledgement of receipt to the developer, citing the exact measured gap and paragraph 4.2.1 of the standard. Demand replacement of the non-compliant windows. If the developer refuses, take the matter to the Nice judicial court. A contradictory expert assessment (your expert plus theirs) will settle the matter. In the meantime, do not sign the handover report without reservations.
📅 Updated on 08/08/2026 — By Cassini Expertise, independent building expert for the 06 & 83 regions. Free quote: 04 22 46 06 04.
To go further:
Frequently asked questions
What should I do about non-compliant windows under a VEFA CCTP?
In the event of non-compliance, you must notify the seller by registered letter with acknowledgement of receipt. The developer must then remedy the compliance defects, since a VEFA contract guarantees that the property matches the plans and the CCTP. If no agreement is reached, you can take the matter to the judicial court.
What recourse do I have if window dimensions are smaller than the plans?
You can request a price reduction or that the property be brought into compliance. Have the discrepancy recorded by an expert or a bailiff. The legal conformity guarantee applies, and the developer is required to correct the dimensions if they don’t meet the CCTP.
What’s the deadline to act on VEFA non-compliance?
You have until handover to report apparent non-compliance. After handover, you have a 10-year period for hidden defects, but for contractual non-compliance, it’s advisable to act quickly, ideally before handover or within the following months.