In short. Cassini Expertise visits with its own professional measuring instruments: a thermo-hygrometer, an anemometer, a laser thermometer, moisture meters and a HIKMICRO B10S thermal camera. Every value in our reports comes from a calibrated instrument that is named for each measurement, never from a visual estimate. We cover the 06, 83 and 13 departments and take the readings in front of you.
Our survey equipment: measurements, not impressions
A sound diagnosis rests on measured figures, not impressions. Cassini Expertise visits with its own professional Trotec measuring instruments. Every value in our reports comes from a calibrated instrument, not from a visual estimate.
The instruments we bring to site
Trotec BC21
Thermo-hygrometer with dew point
Measures the relative humidity of the air and calculates the dew point. It shows whether your indoor air encourages condensation and mould, and under what conditions.
Trotec BA06
Vane anemometer
Measures the actual airflow at the extraction vent. The French order of 24 March 1982 requires 15 m³/h in a bathroom on its own and 30 m³/h if it includes a WC. Without this measurement, nobody can say whether your ventilation system (VMC) is working.
Trotec BP21
Laser infrared thermometer
Non-contact surface temperatures from -35 °C to +800 °C. It locates the thermal bridges and cold walls that cause condensation, which are invisible to the naked eye.
Trotec BM31
Non-destructive moisture meter
Maps residual moisture INSIDE walls, skirting boards and floors, without drilling or damaging anything. It shows whether a wall is still wet after a flood.
Trotec BM22
Moisture meter for timber and building materials
Measures moisture with a pin probe, giving a precise figure for the water content of materials. It is the kind of evidence that can get an insurance file reopened.
The photos above show our own instruments, taken at our office, not manufacturer’s images. When Cassini Expertise visits your property, these instruments come out of the case and every measurement is taken in front of you.
HIKMICRO B10S
Infrared thermal camera with 2 MP optical camera
256×192 IR sensor (SuperIR 640×480), thermal/visual fusion, 3.2″ screen, measuring range from −20 °C to 550 °C, 25 Hz video, 64 GB of storage. It makes the invisible visible: water leaks, insulation defects, underfloor heating and water ingress. Each thermal anomaly is time-stamped and included in the expert report with its image.
Mould sampling
Adhesive tape, swab or dust samples, analysed in a laboratory
Identifies the moulds present (by microscopy or culture) and quantifies them with the swab. The subcontracted laboratory states, under its own responsibility, which moulds are normal and which are not. The laboratory report is interpreted within 20 days at most of receiving the sample. It complements the on-site measurements: the analysis says what is growing, while the dew point and the moisture meter say why.
Why this matters to you

When we measure the airflow of a ventilation system with the BA06 anemometer, take the residual moisture of a wall with the BM31 or calculate a dew point with the BC21, we produce objective values that are hard to dispute. A report built on measured figures carries weight with an insurer, a managing agent (syndic), a lawyer or a court. A report built on “it looks damp” carries none.
Our instruments in use

New for 2026: seeing inside the wall and tracing water
Bosch D-tect 120 professional wall scanner
The Bosch Professional D-tect 120 wall scanner locates what is hidden inside walls before any probing or drilling:
- Plastic pipes: up to 60 mm deep
- Timber studs: up to 38 mm
- Live electrical wires: up to 60 mm
- Ferrous and non-ferrous metals: up to 120 mm
In a survey, it turns doubt into a recorded finding: whether a concealed duct really is there, reinforcement in concrete, or a service buried in a partition. The report then records a dated detection at a measured depth, not a supposition.
Fluorescein leak tracing
When water travels without any visible origin, fluorescein tracing reveals the real path of the leak. A harmless dye is injected into the suspect system, then its route is read under a UV lamp. It is the tool that tells an infiltration from condensation, or a pipe leak from rising damp. It identifies the exact cause, which is what any claim rests on.
These instruments complete the kit: thermal camera, moisture meters, anemometer and pressure test. Every expert report names the instrument used for each measurement.

To understand our moisture instruments: what resistive and capacitive moisture meters really measure (in French).
Frequently asked questions
Do you use your own instruments?
Yes. The photos on this page show our own instruments, taken at our office. Each measurement in the report names the instrument used.
Do you have to drill holes in my walls?
Not to map moisture. The Trotec BM31 reads residual moisture inside walls, skirting boards and floors without drilling. The BM22 uses a pin probe when a precise water-content figure is needed.
How do you check whether my ventilation works?
We measure the actual airflow at the extraction vent with the Trotec BA06 anemometer and compare it with the figures in the French order of 24 March 1982: 15 m³/h in a bathroom on its own, 30 m³/h if it includes a WC.
Read also
- Mould after a flood: who to call (in French)
- Bathroom damp: who is responsible (in French)
- Independent expert: no works sold (in French)
- 2026 guide: choosing a building expert (in French)
Survey carried out by Frédéric Faucouneau, independent building expert, Antibes, Alpes-Maritimes (06), Var (83), Bouches-du-Rhône (13). Last updated: 23 November 2026. Find out more
Last updated 23 November 2026 - Cassini Expertise, independent building expert, departments 06, 83 and 13.