EXPERT ASSESSMENT – VEFA (Off-Plan Sale)

You have just taken delivery of your apartment in a VEFA (off-plan sale) in [Nice](https://cassini-expertise.fr/en/nice-clay-subsidence-cracks/). Comparing the site plan from the building permit with the actual situation on the ground, you have doubts. You take out your tape measure and measure the distance between the façade and the property boundary. The figure you get does not match the one on the plan. The difference is 15, 20, sometimes 30 centimetres. This offset is not just a matter of centimetres on paper. It can call into question compliance with Nice’s planning rules, especially distances to boundary lines or public roads. In many of the cases we see, the developer invokes a “construction tolerance”. But this tolerance has precise limits defined by law.

## What You See, and What It May Hide

![vefa site plan building offset nice legal recourse expertise - Cassini Expertise](https://cassini-expertise.fr/wp-content/uploads/2026/09/vefa-antibes.webp)

*Cassini Expertise – independent building experts*

The symptom is simple: the building is not exactly where the site plan placed it. You see it with the naked eye or by measuring. What no one says: this offset is often not uniform. On a case in Nice last year, we measured an offset of 22 cm on the south façade, but only 8 cm on the east façade. Why? Because the on-site setting-out, carried out by a surveyor from topographic points, can drift during foundation or structural work. The site plan is an ideal projection; reality is shaped by the terrain, the slope and the accuracy of the workmen. In practice, what does this mean? A legal risk if the offset crosses a regulatory threshold, and a technical problem if it affects networks or access.

Planned location (Site plan) Actual location (Building) Δ = 49.5 cm Property boundary Actual distance Planned distance

## Calculation: Composite Standard Deviation

We do not simply subtract. In our assessments, we calculate the planar offset between the plan and the measured position. Formula: d = √(ΔX² + ΔY²). Take a concrete case in Nice: the site plan indicates a building corner at coordinates (X=325417.50, Y=488125.80) in the RGF93/Lambert 93 system. The expert, using a Leica TS16 total station (angular accuracy 1″, linear ±2 mm + 2 ppm), measures the actual point at (X=325417.85, Y=488126.15). Calculation: ΔX = 0.35 m, ΔY = 0.35 m. d = √(0.35² + 0.35²) = √(0.1225 + 0.1225) = √0.245 ≈ 0.495 m. That is an offset of nearly 50 cm. The permitted deviation for building layout is set by the contract documents and the applicable technical standards; Article R462-1 of the Planning Code concerns the declaration of completion of works, not a tolerance. Here, an offset of nearly 50 cm clearly calls for an explanation. What this means concretely: if the regulatory distance to the boundary was 3 metres, it becomes 2.50 m. The building is potentially in breach of Nice’s Local Urban Plan (PLU).

## If the Offset Is Left Uncorrected

In the short term (6 months), nothing seems to move. But the anomaly remains. During a future sale, the planning compliance check may reveal the anomaly. The potential buyer or their notary will request regularisation. In the medium term (2 years), if the offset has reduced a legal distance, a neighbour could bring a claim for abnormal neighbourhood nuisance or non-compliance with planning rules. In a dense city such as Nice, such conflicts can arise. In the long term (5 years), indirect problems can arise: a stormwater drainage system planned to run 1 m from the building ends up at 50 cm, increasing the risk of infiltration during heavy Mediterranean rains. Regularisation after the fact (municipal procedures, possible modification of the building) can be costly, not to mention the loss of property value.

The one-year completion warranty (garantie de parfait achèvement) and the [ten-year builder’s warranty](https://www.service-public.gouv.fr/particuliers/vosdroits/F2034) (garantie décennale) may apply, but for a layout defect the main issue is compliance with the contract (the contractual site plan) and with planning rules. The seller’s obligation to deliver what was agreed (Article 1604 of the Civil Code) is central here. The site plan appended to the VEFA contract binds the developer.

## Recourse and Guarantees

You are not defenceless. The first step is a registered letter with return receipt to the developer, pointing out the observed offset and demanding regularisation or compensation, citing the breach of the contractual site plan and possible non-compliance with Article R462-1 of the Planning Code. If they refuse or downplay it, have the offset documented by an independent expert (surveyor or building expert). Their report, with RMSE calculations and comparison to thresholds, will serve as evidence. As a last resort, the Nice Judicial Court (tribunal judiciaire) has jurisdiction. A court-appointed expert assessment, often ordered in such disputes, will determine whether the offset is unacceptable and its consequences. Do not let a developer tell you “it’s within tolerance” without numerical proof. In Nice as elsewhere, centimetres on a site plan have legal and financial value.

**Further reading:**

- [VEFA Site Plan Discrepancy in Nice: Misplaced Building](https://cassini-expertise.fr/en/vefa-site-plan-discrepancy-nice/)
- [Building Setback Non-Compliant with Planning Permission Site Plan in Nice](https://cassini-expertise.fr/en/building-setback-non-compliant-site-plan-nice/)

## Frequently Asked Questions

### What is VEFA?

VEFA (Vente en l’État Futur d’Achèvement) is a French off-plan property sale where the buyer purchases a property before it is built, with payments made in stages as construction progresses.

### What is a site plan (plan masse)?

A site plan is a scaled drawing showing the location of buildings, boundaries, and other features on a property. It is part of the building permit and the VEFA contract.

### What is the tolerance for building offset?

Under French law (Article R462-1 of the Planning Code), the tolerance for structural elements is generally 5 to 10 cm. Offsets beyond this may require regularisation.

### What should I do if I discover an offset?

Send a registered letter to the developer demanding correction or compensation. If unresolved, hire an independent expert to document the offset and consider legal action.

### What is the RMSE calculation?

RMSE (Root Mean Square Error) is calculated as √(ΔX² + ΔY²), where ΔX and ΔY are the differences in coordinates between the planned and actual building location.

## Frequently asked questions

### What is the legal distance between buildings in Nice VEFA?

In Nice, the legal distance between buildings is generally governed by the local urban plan (PLU). Typically, a minimum distance of 3 metres is required, but this can vary depending on the zone and building height. Always check the specific PLU for your plot.

### Can I sue the seller for building too close to my property in a VEFA?

Yes, you can take legal action if the building violates the PLU or the VEFA contract’s specifications. You may seek damages or require the seller to comply with the setback rules. Consult a lawyer who specialises in construction law to assess your case.

### How can I check the building setback on a VEFA site plan before purchase?

Before signing, compare the site plan with the PLU's offset requirements. Hire an independent surveyor or architect to check the plan's accuracy. Ensure the plan includes all setback distances and that they meet legal standards.

---